    High-temperature insulated wire isn’t an one-size-fits-all product. With respect to the application, different factors go into choosing the proper type of wire to find the done right. In this post, we’ll keep an eye on at what these 4 elements are and exactly how they are able to help with selecting the best high-temperature insulated wire for your specific situation.

    Factor #1: Concept of Electrical Requirements – Operating voltage, conductor temperature rating and current-carrying capacity (aka ampacity) must be met when selecting high-temperature insulated wire. Such wiring is labeled having a temperature rating, that’s determined by a mixture of ambient heat and current-generated heat. Ambient heat is a result of the application being performed whereas current-generated heat is calculated by matching conductor material and diameter to service amperage. You should observe that due to the difficulty in pinning down exact current-carrying capacity, designers often specify higher capacity conductors than theoretical calculations would indicate.

    Factor #2: Environmental Conditions – What’s going on within the wire is not only consideration in relation to selecting the right high-temperature insulated wire. External environmental factors can also be important. Like they could have a damaging influence on both the wire’s insulation and its interior circuitry. Ambient heat, moisture, abrasion, thermal stability, chemical attach, mechanical abuse, low temperature, flame resistance, easy stripping terminating and routing are common environmental conditions that should be compensated for when choosing high-temperature insulated wire. Some factors are discussed in depth further on in this article.

    Factor #3: Conductor Material Type – The wire’s conductor material determines the maximum temperature it could withstand. Situations which need the wire to have the best of temperatures, like high-rise alarms in the eventuality of a fire, may well be more reliably served with nickel-coated copper and nickel conductors, both of which can endure temperatures around 550 degrees Celsius. Copper, nickel-plated and iron conductors conversely holds up under only a maximum variety of 200 to 250 degrees Celsius.

    Factor #4: Current-Carrying Capacity or Ampacity – A lot of the environmental conditions stated above likewise have an impact on high-temperature insulated wire’s power to carry current. Therefore, they have to be weighed in to the equation. Ampacity is measured since the current a conductor can conduct ahead of the combined temperature of both conductor and insulation rises above a permitted limit.

    Conductor size and material, amperage, ambient temperature and insulation type will all play a role may be the wire’s ampacity. The conductor’s diameter and mass are the most influential size considerations. The lesser they are, the reduced the high-temperature insulated wire’s ampacity. As previously talked about from the Factor #3 section, a conductor’s material carries a strong bearing on just how much temperature the wire can withstand knowning that temperature range varies widely. Likewise, various materials produce wide fluctuations in the current-carrying capacity from the wire at the same time.

    Finally, the insulation used in the wire determines the amount heat it dissipates and, in turn, the ampacity. The dissipation problem becomes difficult when wire is enclosed within a tightly confined space, so fire alarms in high-rise ductwork, for instance, pose additional challenges when looking at high-temperature insulated wire options.